{"id":5380,"date":"2026-02-27T16:16:36","date_gmt":"2026-02-27T09:16:36","guid":{"rendered":"https:\/\/onggiosaoviet.vn\/?p=5380"},"modified":"2026-02-27T16:16:36","modified_gmt":"2026-02-27T09:16:36","slug":"bao-lau-can-bao-tri-he-thong-ong-gio-chong-chay-bi-quyet-duy-tri-do-ben-vinh-cuu","status":"publish","type":"post","link":"https:\/\/onggiosaoviet.vn\/en\/bao-lau-can-bao-tri-he-thong-ong-gio-chong-chay-bi-quyet-duy-tri-do-ben-vinh-cuu\/","title":{"rendered":"How Often Does Fire-Resistant Ducting System Need Maintenance? Secrets to Ensuring Lasting Durability."},"content":{"rendered":"<p><span style=\"font-weight: 400;\">In fire protection systems, fire-resistant air ducts (EI) play a vital role in venting smoke and preventing the spread of fire. However, many businesses often have a &quot;install once, use forever&quot; mentality, forgetting that the durability of the air ducts depends heavily on maintenance.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">So how often do fire-resistant duct systems need maintenance, and how long do they actually last? Let&#039;s find out in detail below.<\/span><\/p>\n<figure id=\"attachment_5381\" aria-describedby=\"caption-attachment-5381\" style=\"width: 1324px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-5381 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-6.png\" alt=\"C\u00f4ng nh\u00e2n OGSV \u0111ang thi c\u00f4ng t\u1ea1i d\u1ef1 \u00e1n\" width=\"1324\" height=\"882\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-6.png 1324w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-6-300x200.png 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-6-1024x682.png 1024w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-6-768x512.png 768w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-6-18x12.png 18w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-6-600x400.png 600w\" sizes=\"(max-width: 1324px) 100vw, 1324px\" \/><figcaption id=\"caption-attachment-5381\" class=\"wp-caption-text\"><em>OGSV workers are currently working on the project.<\/em><\/figcaption><\/figure>\n<h3><b>1. Actual lifespan: How long do fire-resistant ductwork last?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Technically, a standard fire-resistant duct system (made from galvanized steel combined with specialized fire-resistant panels or fire-resistant paint) has an average lifespan of... <\/span><b>20 to 25 years<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">However, this lifespan can only be achieved when:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Materials meet standards:<\/b><span style=\"font-weight: 400;\"> Use fire-resistant panels (such as MgO panels, gypsum boards, or fire-resistant mortar) that offer good heat and moisture resistance.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ideal environment:<\/b><span style=\"font-weight: 400;\"> Avoid direct contact with corrosive chemicals or excessively high humidity that could cause the inner steel core to rust.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Construction carried out according to proper techniques:<\/b><span style=\"font-weight: 400;\"> The flange connections and supports are securely installed, preventing pipe deformation over time.<\/span><\/li>\n<\/ul>\n<h3><b>2. How often does a fire-resistant duct system need maintenance?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Despite their high durability, regular maintenance is mandatory to ensure readiness in the event of a fire. According to recommendations from HVAC experts and fire safety standards, the maintenance schedule should be as follows:<\/span><\/p>\n<h4><b>Regular maintenance every 6 months (Surface inspection)<\/b><\/h4>\n<p><span style=\"font-weight: 400;\">This is a quick check to detect signs of physical deterioration:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Inspect the fire-resistant coating for any peeling, cracking, or damage.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Identify any rust spots at the joints, bolts, and nuts.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check the tightness of the heat-resistant gaskets at the flange joints.<\/span><\/li>\n<\/ul>\n<h4><b>Intensive maintenance every 12 months (Operating system)<\/b><\/h4>\n<p><span style=\"font-weight: 400;\">A comprehensive inspection process should be carried out once a year:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Clean the inside of the pipe:<\/b><span style=\"font-weight: 400;\"> Remove accumulated dirt and debris. Excessive dirt can be a fire hazard or reduce airflow during smoke evacuation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Check the fire damper:<\/b><span style=\"font-weight: 400;\"> Ensure that the valve&#039;s springs and temperature sensors remain responsive, capable of opening and closing immediately when temperatures rise.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Reinforce the suspension system:<\/b><span style=\"font-weight: 400;\"> Ensure that the threaded rods and brackets do not become loose due to vibrations from the industrial fan.<\/span><\/li>\n<\/ul>\n<h3><b>3. Why is regular maintenance important for EI ductwork?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Neglecting maintenance not only reduces product lifespan but also creates serious risks:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ensuring legal compliance:<\/b><span style=\"font-weight: 400;\"> Modern high-rise buildings and factories are required to undergo periodic inspections by the fire safety authority. Ventilation systems with damaged protective casings will not be accepted for approval.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Preventing the risk of &quot;disabling&quot;:<\/b><span style=\"font-weight: 400;\"> Fire-resistant paint or panels, if affected by mold or peeling, will lose their insulation properties. In the event of a fire, the pipes will deform within minutes instead of withstanding 60-120 minutes as designed.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Long-term cost savings:<\/b><span style=\"font-weight: 400;\"> Repairing a small section of rusted pipe is always much cheaper than replacing the entire vertical shaft system when it has been severely corroded.<\/span><\/li>\n<\/ol>\n<h3><b>4. Signs that indicate you need immediate duct maintenance.<\/b><\/h3>\n<figure id=\"attachment_5383\" aria-describedby=\"caption-attachment-5383\" style=\"width: 1324px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-5383 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-8.png\" alt=\"C\u00f4ng nh\u00e2n OGSV \u0111ang thi c\u00f4ng t\u1ea1i d\u1ef1 \u00e1n\" width=\"1324\" height=\"882\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-8.png 1324w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-8-300x200.png 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-8-1024x682.png 1024w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-8-768x512.png 768w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-8-18x12.png 18w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-8-600x400.png 600w\" sizes=\"(max-width: 1324px) 100vw, 1324px\" \/><figcaption id=\"caption-attachment-5383\" class=\"wp-caption-text\"><em>OGSV workers are currently working on the project.<\/em><\/figcaption><\/figure>\n<p><span style=\"font-weight: 400;\">Don&#039;t wait until your scheduled maintenance if you notice the following symptoms in your system:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">There are strange noises, a whistling sound coming from the joints (a sign of air leaks).<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The fire-resistant paint is blistering or the outer covering is damp and rotting.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The airflow at the vents has decreased unusually.<\/span><\/li>\n<\/ul>\n<h3><b>Conclude<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The answer to <\/span><b>\u201c&quot;How long do fire-resistant air ducts last?&quot;\u201d<\/b><span style=\"font-weight: 400;\"> The key lies in how you maintain the system. With proper maintenance (every 6-12 months), your system will always be ready to fight fires, providing absolute safety for people and property.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Trong h\u1ec7 th\u1ed1ng ph\u00f2ng ch\u00e1y ch\u1eefa ch\u00e1y (PCCC), \u1ed1ng gi\u00f3 ch\u1ed1ng ch\u00e1y (EI) \u0111\u00f3ng vai tr\u00f2 s\u1ed1ng c\u00f2n gi\u00fap tho\u00e1t kh\u00f3i v\u00e0 ng\u0103n ch\u1eb7n l\u1eeda lan truy\u1ec1n. Tuy nhi\u00ean, nhi\u1ec1u doanh nghi\u1ec7p th\u01b0\u1eddng c\u00f3 t\u00e2m l\u00fd &#8220;l\u1eafp m\u1ed9t l\u1ea7n d\u00f9ng m\u00e3i m\u00e3i&#8221; m\u00e0 qu\u00ean m\u1ea5t r\u1eb1ng, \u0111\u1ed9 b\u1ec1n c\u1ee7a \u1ed1ng gi\u00f3 ph\u1ee5 thu\u1ed9c r\u1ea5t l\u1edbn [&hellip;]<\/p>","protected":false},"author":3,"featured_media":5381,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[199,154,200],"class_list":["post-5380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tin-tuc","tag-bao-tri-ong-gio","tag-cong-trinh-ong-gio-hai-phong","tag-do-ben-ong-gio-hai-phong"],"_links":{"self":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/comments?post=5380"}],"version-history":[{"count":1,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5380\/revisions"}],"predecessor-version":[{"id":5384,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5380\/revisions\/5384"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media\/5381"}],"wp:attachment":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media?parent=5380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/categories?post=5380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/tags?post=5380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}