{"id":5417,"date":"2026-02-28T10:39:54","date_gmt":"2026-02-28T03:39:54","guid":{"rendered":"https:\/\/onggiosaoviet.vn\/?p=5417"},"modified":"2026-02-28T10:39:54","modified_gmt":"2026-02-28T03:39:54","slug":"tieu-chuan-pccc-ap-dung-cho-he-thong-ong-gio-trong-cong-trinh-xay-dung","status":"publish","type":"post","link":"https:\/\/onggiosaoviet.vn\/en\/tieu-chuan-pccc-ap-dung-cho-he-thong-ong-gio-trong-cong-trinh-xay-dung\/","title":{"rendered":"Fire safety standards applicable to ventilation systems in construction projects."},"content":{"rendered":"<p><span style=\"font-weight: 400;\">In current civil and industrial construction projects, <\/span><b>Fire safety standards for duct systems<\/b><span style=\"font-weight: 400;\"> This is a mandatory requirement during design, construction, and acceptance testing. The duct system not only serves the purpose of ventilation and air conditioning but is also directly related to... <\/span><b>fire safety and evacuation<\/b><span style=\"font-weight: 400;\">. Failure to comply with fire safety standards can lead to serious risks and render a building unfit for use.<\/span><\/p>\n<figure id=\"attachment_5418\" aria-describedby=\"caption-attachment-5418\" style=\"width: 1324px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-5418 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-14.png\" alt=\"C\u00f4ng nh\u00e2n OGSV \u0111ang l\u00e0m vi\u1ec7c nh\u00e0 x\u01b0\u1edfng s\u1ea3n xu\u1ea5t.\" width=\"1324\" height=\"882\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-14.png 1324w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-14-300x200.png 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-14-1024x682.png 1024w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-14-768x512.png 768w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-14-18x12.png 18w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-14-600x400.png 600w\" sizes=\"(max-width: 1324px) 100vw, 1324px\" \/><figcaption id=\"caption-attachment-5418\" class=\"wp-caption-text\"><em>OGSV workers are working in the production workshop.<\/em><\/figcaption><\/figure>\n<h3><b>1. The role of duct systems in fire prevention and control.<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">When a fire occurs, smoke and toxic gases are the greatest dangers to human life. <\/span><b>Fire protection duct system<\/b><span style=\"font-weight: 400;\"> Its duties include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Remove smoke and toxic gases from the fire area.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Prevent smoke from spreading to other areas.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Assist in creating pressure for the emergency exit.<\/span><\/li>\n<\/ul>\n<p>Especially in the basement, corridors, and emergency stairwells, <b>smoke exhaust duct system<\/b><span> It plays a crucial role in ensuring safety and minimizing damage.<\/span><\/p>\n<h3><b>2. Mandatory fire safety standards applicable to duct systems.<\/b><\/h3>\n<figure id=\"attachment_5419\" aria-describedby=\"caption-attachment-5419\" style=\"width: 1324px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-5419 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-15.png\" alt=\"C\u00f4ng nh\u00e2n OGSV \u0111ang l\u00e0m vi\u1ec7c t\u1ea1i x\u01b0\u1edfng s\u1ea3n xu\u1ea5t. \" width=\"1324\" height=\"882\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-15.png 1324w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-15-300x200.png 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-15-1024x682.png 1024w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-15-768x512.png 768w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-15-18x12.png 18w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/02\/Thiet-ke-chua-co-ten-15-600x400.png 600w\" sizes=\"(max-width: 1324px) 100vw, 1324px\" \/><figcaption id=\"caption-attachment-5419\" class=\"wp-caption-text\"><em>OGSV workers are working in the production workshop. <\/em><\/figcaption><\/figure>\n<p><span style=\"font-weight: 400;\">According to current regulations, the duct system in a building must meet the following basic requirements:<\/span><\/p>\n<h3><b>2.1. Duct Materials<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Air ducts must be manufactured from materials. <\/span><b>Non-flammable or difficult to burn<\/b><span style=\"font-weight: 400;\">, Commonly used materials include galvanized steel, steel, and stainless steel.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">For areas with high demands, the following is required: <\/span><b>EI fireproof duct<\/b><span style=\"font-weight: 400;\"> according to the specified fire resistance time (EI30, EI60, EI90\u2026).<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<\/ul>\n<h3><b>2.2. Heat resistance and flame retardancy<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The fire protection duct system must ensure <\/span><b>No deformation, no collapse.<\/b><span style=\"font-weight: 400;\"> during the standard fire duration.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Joints, flanges, and gaskets must be leak-proof.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<\/ul>\n<h3><b>3. Fire fighting dampers and associated equipment<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">An integral part of the system is <\/span><b>fire fighting air damper<\/b><span style=\"font-weight: 400;\">:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Fire dampers and smoke dampers must automatically close when the temperature exceeds the permissible limit.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ventilation dampers must be installed correctly at points where they penetrate walls, floors, or fire compartments.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Incorrect installation or absence of fire dampers can cause smoke and fire to spread rapidly, leading to a loss of fire control.<\/span><\/p>\n<h3><b>4. Requirements for installation and construction of fire protection duct systems.<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The duct system needs to be:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Install according to the approved fire safety design drawings.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Arrange the supports and pipe hangers to ensure they can withstand the pressure when the temperature rises.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Through walls and floors, all penetrations must be sealed with fire-resistant materials that meet standards.<\/span><\/li>\n<\/ul>\n<p>Besides, <b>smoke exhaust duct system<\/b><span> Its ability to operate independently in an emergency needs to be tested.<\/span><\/p>\n<h3><b>5. Inspection, acceptance testing, and maintenance according to fire safety standards.<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">After installation, the duct system must:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Inspected and tested as required by the fire safety authority.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Only after passing the acceptance test will the equipment be put into use.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">During operation, the investor needs to:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Regular maintenance of fire protection duct and damper systems.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ensure the system is always ready to operate in the event of a fire or explosion.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<\/ul>\n<h3><b>Conclude<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Follow <\/span><b>Fire safety standards for duct systems<\/b><span style=\"font-weight: 400;\"> It is not only a legal requirement but also a crucial factor in protecting people and property. The choice... <\/span><b>A manufacturer and installer of fire protection ductwork that meets standards.<\/b><span style=\"font-weight: 400;\"> This will help ensure the project is approved and accepted smoothly, and operates safely in the long term.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Trong c\u00e1c c\u00f4ng tr\u00ecnh d\u00e2n d\u1ee5ng v\u00e0 c\u00f4ng nghi\u1ec7p hi\u1ec7n nay, ti\u00eau chu\u1ea9n PCCC cho h\u1ec7 th\u1ed1ng \u1ed1ng gi\u00f3 l\u00e0 y\u00eau c\u1ea7u b\u1eaft bu\u1ed9c khi thi\u1ebft k\u1ebf, thi c\u00f4ng v\u00e0 nghi\u1ec7m thu. H\u1ec7 th\u1ed1ng \u1ed1ng gi\u00f3 kh\u00f4ng ch\u1ec9 \u0111\u1ea3m nhi\u1ec7m vai tr\u00f2 th\u00f4ng gi\u00f3, \u0111i\u1ec1u h\u00f2a m\u00e0 c\u00f2n li\u00ean quan tr\u1ef1c ti\u1ebfp \u0111\u1ebfn an to\u00e0n [&hellip;]<\/p>","protected":false},"author":3,"featured_media":5418,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[216,193,217],"class_list":["post-5417","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tin-tuc","tag-he-thong-ong-gio-thoat-khoi","tag-ong-gio-chong-chay","tag-pccc-cho-he-thong-ong-gio"],"_links":{"self":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5417","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/comments?post=5417"}],"version-history":[{"count":2,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5417\/revisions"}],"predecessor-version":[{"id":5421,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5417\/revisions\/5421"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media\/5418"}],"wp:attachment":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media?parent=5417"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/categories?post=5417"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/tags?post=5417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}