{"id":5476,"date":"2026-03-09T10:56:43","date_gmt":"2026-03-09T03:56:43","guid":{"rendered":"https:\/\/onggiosaoviet.vn\/?p=5476"},"modified":"2026-03-09T10:56:43","modified_gmt":"2026-03-09T03:56:43","slug":"checklist-nghiem-thu-he-thong-ong-gio","status":"publish","type":"post","link":"https:\/\/onggiosaoviet.vn\/en\/checklist-nghiem-thu-he-thong-ong-gio\/","title":{"rendered":"Ductwork System Acceptance Checklist: Standards to be Checked on-Site"},"content":{"rendered":"<figure id=\"attachment_5477\" aria-describedby=\"caption-attachment-5477\" style=\"width: 2048px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-5477 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4.png\" alt=\"C\u00f4ng nh\u00e2n OGSV \u0111ang l\u00e0m vi\u1ec7c t\u1ea1i c\u00f4ng tr\u01b0\u1eddng \" width=\"2048\" height=\"1536\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4.png 2048w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4-300x225.png 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4-1024x768.png 1024w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4-768x576.png 768w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4-1536x1152.png 1536w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4-16x12.png 16w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-bai-4-600x450.png 600w\" sizes=\"(max-width: 2048px) 100vw, 2048px\" \/><figcaption id=\"caption-attachment-5477\" class=\"wp-caption-text\"><em>OGSV workers are working at the construction site. <\/em><\/figcaption><\/figure>\n<p><span style=\"font-weight: 400;\">In HVAC system installations, ductwork acceptance testing is a crucial step to ensure the system operates efficiently, safely, and according to design specifications. Inadequate testing can lead to air leakage, vibration, or reduced operational efficiency.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Below is a checklist for on-site acceptance testing of the duct system, helping engineers and investors to fully and accurately control the quality of construction.<\/span><\/p>\n<h2><b>Checklist for acceptance testing of the duct system at the construction site.<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">When conducting acceptance testing of HVAC ductwork, it is necessary to check important aspects from materials and installation to airtightness and insulation to ensure the system meets technical standards.<\/span><\/p>\n<h2><b>Check the airtightness of the duct system.<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">One of the most important criteria when inspecting a duct system is the tightness of the joints.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The points to check include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Flange joints must be tightened with bolts to the correct standard.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Silicone sealant or specialized tape is used to seal the joints.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">There is no air leakage at the joints.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The flexible hose sections must be securely fastened with hose clamps.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">If the system is not airtight, airflow will be lost, reducing the efficiency of the entire air conditioning and ventilation system.<\/span><\/p>\n<h2><b>Mounting bracket spacing and suspension system rigidity<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">During the installation and acceptance of the ductwork, the spacing of the hangers must comply with technical standards to ensure system stability and prevent vibration.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Some common standards:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Spacing of horizontal duct hangers: 2-3 m depending on duct size.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">For larger ductwork, the spacing can be shorter to increase rigidity.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suspension rods, bolts, and support bars must be securely fastened to the ceiling structure.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Additionally, the following should be checked:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">There is no duct sagging.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The hangers are painted with anti-rust paint or galvanized.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Ensuring the suspension system meets standards helps increase its lifespan and reduce noise during operation.<\/span><\/p>\n<h2><b>Inspect the duct insulation.<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">For air conditioning systems, duct insulation plays a crucial role in preventing heat loss and limiting condensation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The criteria to be checked include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The insulation layer thickness is as designed.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The insulation surface is not torn or open.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The insulation joints are sealed with specialized tape.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The outer silver layer is applied smoothly and aesthetically.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">If the insulation layer is not up to standard, condensation may occur, affecting the ceiling and surrounding interior furnishings.<\/span><\/p>\n<figure id=\"attachment_5478\" aria-describedby=\"caption-attachment-5478\" style=\"width: 2048px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-5478 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1.jpg\" alt=\"C\u00f4ng nh\u00e2n OGSV \u0111ang l\u00e0m vi\u1ec7c t\u1ea1i x\u01b0\u1edfng s\u1ea3n xu\u1ea5t\" width=\"2048\" height=\"1365\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1.jpg 2048w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1-300x200.jpg 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1-1024x683.jpg 1024w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1-768x512.jpg 768w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1-1536x1024.jpg 1536w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1-18x12.jpg 18w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-Bai-2-thang-3-1-600x400.jpg 600w\" sizes=\"(max-width: 2048px) 100vw, 2048px\" \/><figcaption id=\"caption-attachment-5478\" class=\"wp-caption-text\"><em>OGSV workers are working in the production workshop. <\/em><\/figcaption><\/figure>\n<h2><b>Check the installation location and dimensions of the air duct.<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">During the on-site acceptance testing of the duct system, engineers also need to compare it with the design drawings to ensure:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The duct dimensions match the drawing.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The duct alignment is correct according to the design.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The air vents are installed correctly.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">There are enough access doors for system maintenance.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">This inspection helps the system operate at the correct flow rate and facilitates future maintenance.<\/span><\/p>\n<h2><b>Inspection of aesthetics and construction safety.<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">In addition to technical standards, the ductwork acceptance process also needs to evaluate aesthetic and safety factors.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The duct surface is not dented.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The joints are aligned and neat.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">There are no sharp edges that could endanger the operator.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The construction area has been cleaned thoroughly.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">A properly installed duct system not only ensures operational efficiency but also enhances the durability and professionalism of the project.<\/span><\/p>\n<h2><b>Conclude<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Completing the entire ductwork system acceptance checklist ensures that the ventilation system operates stably, saves energy, and meets technical standards.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The project owner and supervising engineer should carefully check factors such as duct tightness, mounting bracket spacing, insulation layer, and installation location to ensure construction quality before putting the system into operation.<\/span><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Trong c\u00e1c c\u00f4ng tr\u00ecnh h\u1ec7 th\u1ed1ng HVAC, vi\u1ec7c nghi\u1ec7m thu h\u1ec7 th\u1ed1ng \u1ed1ng gi\u00f3 l\u00e0 b\u01b0\u1edbc quan tr\u1ecdng nh\u1eb1m \u0111\u1ea3m b\u1ea3o h\u1ec7 th\u1ed1ng ho\u1ea1t \u0111\u1ed9ng hi\u1ec7u qu\u1ea3, an to\u00e0n v\u00e0 \u0111\u00fang thi\u1ebft k\u1ebf. N\u1ebfu qu\u00e1 tr\u00ecnh ki\u1ec3m tra kh\u00f4ng \u0111\u1ea7y \u0111\u1ee7, h\u1ec7 th\u1ed1ng th\u00f4ng gi\u00f3 c\u00f3 th\u1ec3 g\u1eb7p ph\u1ea3i t\u00ecnh tr\u1ea1ng th\u1ea5t tho\u00e1t gi\u00f3, rung [&hellip;]<\/p>","protected":false},"author":3,"featured_media":5477,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[238,239,240],"class_list":["post-5476","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tin-tuc","tag-checklist-nghiem-thu-he-thong-ong-gio","tag-he-thong-ong-gio","tag-he-thong-ong-gio-tai-cong-truong"],"_links":{"self":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/comments?post=5476"}],"version-history":[{"count":2,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5476\/revisions"}],"predecessor-version":[{"id":5480,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5476\/revisions\/5480"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media\/5477"}],"wp:attachment":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media?parent=5476"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/categories?post=5476"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/tags?post=5476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}