{"id":5487,"date":"2026-03-09T15:28:19","date_gmt":"2026-03-09T08:28:19","guid":{"rendered":"https:\/\/onggiosaoviet.vn\/?p=5487"},"modified":"2026-03-09T15:28:19","modified_gmt":"2026-03-09T08:28:19","slug":"tieu-chuan-ong-gio-va-mieng-gio-cho-nha-may-duoc-pham-dien-tu","status":"publish","type":"post","link":"https:\/\/onggiosaoviet.vn\/en\/tieu-chuan-ong-gio-va-mieng-gio-cho-nha-may-duoc-pham-dien-tu\/","title":{"rendered":"Cleanroom: Standards for air ducts and vents in pharmaceutical and electronics factories."},"content":{"rendered":"<figure id=\"attachment_5488\" aria-describedby=\"caption-attachment-5488\" style=\"width: 735px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-5488 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-1-Bai-6.jpg\" alt=\"H\u1ec7 th\u1ed1ng \u1ed1ng gi\u00f3 cho cleanroom v\u1ec1 d\u01b0\u1ee3c ph\u1ea9m - \u0111i\u1ec7n t\u1eed\" width=\"735\" height=\"490\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-1-Bai-6.jpg 735w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-1-Bai-6-300x200.jpg 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-1-Bai-6-18x12.jpg 18w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-1-Bai-6-600x400.jpg 600w\" sizes=\"(max-width: 735px) 100vw, 735px\" \/><figcaption id=\"caption-attachment-5488\" class=\"wp-caption-text\"><em>Air duct system for cleanrooms in pharmaceutical and electronics industries. <\/em><\/figcaption><\/figure>\n<p><span style=\"font-weight: 400;\">In industries requiring high precision and hygiene, such as pharmaceuticals, electronic components, or medical devices, cleanroom systems play a crucial role. One of the key factors determining the effectiveness of a cleanroom is its duct and vent system, which helps control airflow, remove dust, and maintain a standard-compliant environment.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The design and construction of cleanroom ductwork must adhere to numerous stringent technical standards to ensure that the production environment consistently meets the required cleanliness levels.<\/span><\/p>\n<h2><b>Cleanroom duct standards in HVAC systems<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">In cleanroom constructions, cleanroom duct systems must ensure high airtightness, smooth surfaces, and minimize dust generation during operation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Some important standards include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Air duct materials commonly used include galvanized sheet metal or stainless steel with a smooth surface.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The joints must be completely airtight, preventing any air leaks.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Duct systems should minimize sharp bends and complex curves to reduce dust accumulation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The inside of the ductwork must be thoroughly cleaned before installation.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">In addition, duct systems in cleanrooms often undergo leak testing to ensure they meet HVAC system technical standards for tightness.<\/span><\/p>\n<h2><b>Cleanroom air vent standards<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Besides ductwork, cleanroom air vents are also important components that help distribute airflow evenly throughout the production space.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Common types of air vents used in cleanrooms include:<\/span><\/p>\n<h3><b>Air intake vents with HEPA filters<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">This type of air vent is common in pharmaceutical and electronics factories. HEPA filters remove ultrafine dust particles from the air before it enters the cleanroom.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Advantage:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Effective dust filtration up to 99,97% for particles as small as 0.3 microns.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Helps maintain cleanliness levels according to cleanroom standards.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Even air flow distribution<\/span><\/li>\n<\/ul>\n<h3><b>Return air vents and exhaust air vents<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The return air vents are responsible for collecting air from the cleanroom and returning it to the treatment system.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The following criteria must be met:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The air vent surface is easy to clean and resistant to dust accumulation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The design avoids dead spaces where dust can accumulate.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">It can be easily disassembled for maintenance.<\/span><\/li>\n<\/ul>\n<h2><b>Standards for installing duct systems in cleanrooms.<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The construction process for cleanroom duct systems must follow strict procedures to avoid contamination.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Some important requirements:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The air duct must be sealed at both ends during transportation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The installation area must be clean before construction begins.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Construction workers must adhere to cleanroom hygiene procedures.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The system needs to be inspected and cleaned before operation.<\/span><\/li>\n<\/ul>\n<h2><b>The role of duct systems in cleanrooms<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A standard cleanroom duct and air vent system offers numerous benefits to a manufacturing plant:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Maintain a clean and stable air environment.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Limit dust and microbial contamination.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ensuring product quality in the pharmaceutical and electronics industries.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Improve the operational efficiency of your HVAC system.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">As a result, cleanrooms can meet the stringent standards of modern industrial production.<\/span><\/p>\n<figure id=\"attachment_5489\" aria-describedby=\"caption-attachment-5489\" style=\"width: 2048px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-5489 size-full\" src=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6-.png\" alt=\"Gia c\u00f4ng t\u00f4n m\u1ea1 k\u1ebdm b\u1eb1ng m\u00e1y t\u1ea1o h\u00ecnh t\u1ea1i nh\u00e0 m\u00e1y OGSV \u2013 c\u00f4ng ngh\u1ec7 gi\u00fap s\u1ea3n xu\u1ea5t \u1ed1ng gi\u00f3 HVAC \u0111\u1ea1t \u0111\u1ed9 b\u1ec1n, \u0111\u1ed9 k\u00edn v\u00e0 ti\u00eau chu\u1ea9n k\u1ef9 thu\u1eadt cao\" width=\"2048\" height=\"1536\" srcset=\"https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6-.png 2048w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6--300x225.png 300w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6--1024x768.png 1024w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6--768x576.png 768w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6--1536x1152.png 1536w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6--16x12.png 16w, https:\/\/onggiosaoviet.vn\/wp-content\/uploads\/2026\/03\/Anh-2-Bai-6--600x450.png 600w\" sizes=\"(max-width: 2048px) 100vw, 2048px\" \/><figcaption id=\"caption-attachment-5489\" class=\"wp-caption-text\"><em>Galvanized steel sheet processing using forming machines at the OGSV factory \u2013 a technology that helps produce HVAC ductwork with high durability, airtightness, and technical standards.<\/em><\/figcaption><\/figure>\n<h2><b>Conclude<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The design and construction of cleanroom ductwork must adhere to strict technical standards to ensure a high level of cleanliness in the production environment. Factors such as duct tightness, air outlet quality, HEPA filtration systems, and installation procedures all play a crucial role in the operational efficiency of the cleanroom.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For pharmaceutical and electronics manufacturing plants, investing in a standard cleanroom duct system is crucial to ensuring product quality and meeting international standards.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Trong c\u00e1c ng\u00e0nh s\u1ea3n xu\u1ea5t y\u00eau c\u1ea7u \u0111\u1ed9 ch\u00ednh x\u00e1c v\u00e0 v\u1ec7 sinh cao nh\u01b0 d\u01b0\u1ee3c ph\u1ea9m, linh ki\u1ec7n \u0111i\u1ec7n t\u1eed hay thi\u1ebft b\u1ecb y t\u1ebf, h\u1ec7 th\u1ed1ng ph\u00f2ng s\u1ea1ch (Cleanroom) \u0111\u00f3ng vai tr\u00f2 c\u1ef1c k\u1ef3 quan tr\u1ecdng. M\u1ed9t trong nh\u1eefng y\u1ebfu t\u1ed1 quy\u1ebft \u0111\u1ecbnh hi\u1ec7u qu\u1ea3 c\u1ee7a ph\u00f2ng s\u1ea1ch ch\u00ednh l\u00e0 h\u1ec7 th\u1ed1ng \u1ed1ng [&hellip;]<\/p>","protected":false},"author":3,"featured_media":5489,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[243,242,244],"class_list":["post-5487","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tin-tuc","tag-tieu-chuan-ong-gio-cho-nha-may-dien-tu","tag-tieu-chuan-ong-gio-cho-nha-may-duoc-pham","tag-tieu-chuan-ong-gio-phong-sach"],"_links":{"self":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/comments?post=5487"}],"version-history":[{"count":1,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5487\/revisions"}],"predecessor-version":[{"id":5490,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/posts\/5487\/revisions\/5490"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media\/5489"}],"wp:attachment":[{"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/media?parent=5487"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/categories?post=5487"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onggiosaoviet.vn\/en\/wp-json\/wp\/v2\/tags?post=5487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}